Atlas / Skills / cyberstrikeus / T0838 Modify Alarm Settings

T0838 Modify Alarm SettingsCAUTION

skills/cyberstrikeus/t0838-modify-alarm-settings

Open-source AI-powered offensive security harness for automated penetration testing.

Verdict
CAUTION
Grade
B
Trust score
89 /100
Version
18.1
Hosts
—
License
AGPL-3.0
Stars
3,185
01

Overview

Open-source AI-powered offensive security harness for automated penetration testing.

Read from source at commit eaf7d03223fcOBSERVED · 2026-10-18
Advertisement
02

What it tells the agent

The instruction file, verbatim from the audited commit — this is the text the model reads, and the surface the audit's instruction layer examines. Quoted here so you can judge it without cloning anything.

---
name: "T0838_modify-alarm-settings"
description: "Adversaries may modify alarm settings to prevent alerts that may inform operators of their presence or to prevent responses to dangerous and unintended scenarios."
category: "business-logic"
version: "18.1"
author: "cyberstrike-official"
tags:
  - mitre-attack
  - ics
  - t0838
  - inhibit-response-function
technique_id: "T0838"
tactic: "inhibit-response-function"
all_tactics:
  - inhibit-response-function
platforms:
  - ICS
mitre_url: "https://attack.mitre.org/techniques/T0838"
tech_stack:
  - ics
cwe_ids:
  - CWE-400
chains_with: []
prerequisites: []
severity_boost: {}
---

# T0838 Modify Alarm Settings

## High-Level Description

Adversaries may modify alarm settings to prevent alerts that may inform operators of their presence or to prevent responses to dangerous and unintended scenarios. Reporting messages are a standard part of data acquisition in control systems. Reporting messages are used as a way to transmit system state information and acknowledgements that specific actions have occurred. These messages provide vital information for the management of a physical process, and keep operators, engineers, and administrators aware of the state of system devices and physical processes.

If an adversary is able to change the reporting settings, certain events could be prevented from being reported. This type of modification can also prevent operators or devices from performing actions to keep the system in a safe state. If critical reporting messages cannot trigger these actions then a Impact could occur.

In ICS environments, the adversary may have to use Alarm Suppression or contend with multiple alarms and/or alarm propagation to achieve a specific goal to evade detection or prevent intended responses from occurring. Methods of suppression often rely on modification of alarm settings, such as modifying in memory code to fixed values or tampering with assembly level instruction code.

## Kill Chain Phase

- Inhibit Response Function (TA0107)

**Platforms:** ICS

## What to Check

- [ ] Identify if Modify Alarm Settings technique is applicable to target ICS environment
- [ ] Check ICS/SCADA systems for indicators of Modify Alarm Settings
- [ ] Verify mitigations are bypassed or absent (7 known mitigations)
- [ ] Assess detection coverage (1 detection strategies)

## How to Test

### Identify Attack Surface

Determine if the target ICS/SCADA environment is susceptible to Modify Alarm Settings by examining operational technology systems and network architecture.

### Assess Existing Defenses

Review whether mitigations for T0838 are in place. If defenses are absent or misconfigured, this technique may be exploitable in the ICS environment.

## Remediation Guide

### M0804 Human User Authentication

All field controllers should require users to authenticate for all remote or local management sessions. The authentication mechanisms should also support Account Use Policies, Password Policies, and User Account Management.

### M0930 Network Segmentation

Segment operational network and systems to restrict access to critical system functions to predetermined management systems.

### M0807 Network Allowlists

Use host-based allowlists to prevent devices from accepting connections from unauthorized systems. For example, allowlists can be used to ensure devices can only connect with master stations or known management/engineering workstations.

### M0813 Software Process and Device Authentication

Authenticate connections fromsoftware and devices to prevent unauthorized systems from accessing protected management functions.

### M0800 Authorization Enforcement

Only authorized personnel should be able to change settings for alarms.

### M0918 User Account Management

Limit privileges of user accounts and groups so that only designated administrators or engineers can interact with alarm management and alarm configuration thresholds.

### M0801 Access Management

All devices or systems changes, including all administrative functions, should require authentication. Consider using access management technologies to enforce authorization on all management interface access attempts, especially when the device does not inherently provide strong authentication and authorization functions.

## Detection

### Detection of Modify Alarm Settings

## Risk Assessment

| Finding                                    | Severity | Impact                    |
| ------------------------------------------ | -------- | ------------------------- |
| Modify Alarm Settings technique applicable | Low      | Inhibit Response Function |

## CWE Categories

| CWE ID  | Title                             |
| ------- | --------------------------------- |
| CWE-400 | Uncontrolled Resource Consumption |

## References

- [Jos Wetzels, Marina Krotofil 2019](https://troopers.de/downloads/troopers19/TROOPERS19_NGI_IoT_diet_poisoned_fruit.pdf)
- [MITRE ATT&CK ICS - T0838](https://attack.mitre.org/techniques/T0838)
03

Trust audit

CAUTIONgrade B · trust 89/100 Install with care. The audit found things worth knowing before you trust its output.

LayerWhat it checksResult
L0Provenance & inventoryWARN
L1Static analysis of the codeNA
L2Instruction surface (what it tells the agent)PASS
L3Class-specific surfacePASS
L4Behavioural (sandbox)SKIPPED

What the source does

Filesystem
none-observed
Network
none-observed
Shell
none-observed
Dependencies
pinned
Secrets in source
none-found

Findings (5)

MEDIUMInventory / provenance · inv.symlink · CWE-1104
packages/app/public/apple-touch-icon-v3.png
packages/app/public/apple-touch-icon-v3.png
Why it matters. link not followed
MEDIUMInventory / provenance · inv.symlink · CWE-1104
packages/app/public/apple-touch-icon.png
packages/app/public/apple-touch-icon.png
Why it matters. link not followed
MEDIUMInventory / provenance · inv.symlink · CWE-1104
packages/app/public/favicon-96x96-v3.png
packages/app/public/favicon-96x96-v3.png
Why it matters. link not followed
MEDIUMInventory / provenance · inv.symlink · CWE-1104
packages/app/public/favicon-96x96.png
packages/app/public/favicon-96x96.png
Why it matters. link not followed
MEDIUMInventory / provenance · inv.symlink · CWE-1104
packages/app/public/favicon-v3.ico
packages/app/public/favicon-v3.ico
Why it matters. link not followed

Gates applied: no_behavioural_pass.

Audited 2026-10-18 · audit v0.4.1 · source sha eaf7d03223fcfull audit observations/trust-audit/skill/cyberstrikeus__t0838_modify-alarm-settings.json · Report an issue / request a re-scan
04

Audit history

Every audit this skill has had.

DateSourceVerdictGradeScoreChange
2026-10-18eaf7d03223fcCAUTIONB89first audit
05

Questions

What does the T0838 Modify Alarm Settings skill do?

Open-source AI-powered offensive security harness for automated penetration testing.

Is T0838 Modify Alarm Settings safe to install?

With care. The audit graded it B (89/100) and found 5 things worth knowing before you trust this skill, listed below with the exact line each was found on.

What can T0838 Modify Alarm Settings access on my machine?

The audit observed no filesystem, network or shell use at all in its source.

How current is this page?

The grade is for one exact copy of the source (eaf7d03223fc), read on 2026-10-18. The repository is watched, and a new audit runs when it changes — this is the first audit.

Add this badge to your README

Shows this page's audit result and links back to it. It updates when the audit does.

ModelsAtlas audit badge

Markdown
[![ModelsAtlas audit: T0838 Modify Alarm Settings](https://modelsatlas.com/skills/cyberstrikeus/t0838-modify-alarm-settings/badge.svg)](https://modelsatlas.com/skills/cyberstrikeus/t0838-modify-alarm-settings/)

Not your listing, or something out of date? Claim or update your listing.

Advertisement